CATETER DE TENCKHOFF PDF

  • May 13, 2019

This booklet has information you need to know to help you care for a Tenckhoff catheter at home. You can use it to learn more about: • Pleural effusion and. Over a period of 33 months a total of 2, peritoneal dialyses were carried out by means of indwelling Tenckhoff catheters in 65 patients suffering from terminal .

Author: Yozshumuro Grokora
Country: Australia
Language: English (Spanish)
Genre: Finance
Published (Last): 1 November 2010
Pages: 58
PDF File Size: 17.24 Mb
ePub File Size: 17.7 Mb
ISBN: 974-1-84223-199-2
Downloads: 29906
Price: Free* [*Free Regsitration Required]
Uploader: Takazahn

The patient refused surgical correction and was transferred to the haemodialysis programme.

Open in a separate window. An Oreopoulos-Zellerman catheter was used. Two catheters were removed because of technical complications in the postoperative period. D, Yardimsever M, Ersoy F. Furthermore, laparoscopy allows for release of peritoneal adhesions if necessary. Careful clinical evaluation and appropriate investi- gations are needed to exclude surgical causes of acute abdomen.

Periumbilical 12mm port for the catheter and left pararectus port with 12mm optics. Surgical complications of continuous ambulatory peritoneal dialysis.

Mortality was not related to PD or to the catheter. According to our experience, we had 0. Print Send to a friend Export reference Mendeley Statistics. The catheter is intended to keep the internal portion from migrating out of position and to decrease stress on the exit site by the external portion, which often occurs when a straight catheter is manually curved during placement.

  GRACELAND ABANI PDF

Use of Tenckhoff Catheter for Peritoneal Dialysis in Terminal Renal Failure

Based on our experience, the obstruction rate was 3. A silicone bead rests just inside the peritoneum and is designed to prevent dialysate leakage. Pneumoperitoneum — Rare complication in end stage renal disease patients on automated peritoneal dialysis. The Tenckhoff catheter was found to be valuable for peritoneal dialysis as a short-term measure, especially in patients in whom haemodialysis was not immediately feasible, in borderline cases when kidney function was not too seriously impaired, and as an alternative to haemodialysis when that was interrupted by complications.

Mean operative time was 32 minutes range: Rua Xavier Cordeiro, 30 Lisboa secretariado.

Peritoneal Dialysis Catheters

We assumed a DP technic related pneumoperitoneum. The optics were placed through this trocar and the catheter with the guide was placed through the periumbilical trocar.

All procedures tenckhoff completed laparoscopically with two 12mm ports.

Laparoscopic introduction of a continuous ambulatory peritoneal dialysis CAPD catheter by a two-puncture technique. Pnemoperitoneum in peritoneal dialysis patients is a rare complication; however it should be considered in differential diagnosis to avoid an unnecessary laparotomy that will compromise the dialytic options.

Home Articles in press Archive. Continuing navigation will be considered as acceptance of this use. Am J Kidney Dis ; An Oreopoulos-Zellerman catheter was used. Patients who remained in the hospital after 24 hours of the procedure did so for medical problems unrelated to the procedure. One patient had catheter obstruction in the first 24 hours after placement and required surgical revision and relocation. Both the presternal and intraperitoneal segments can be trimmed in order to custom fit the patient.

  DUCHESS OF MALFI AS A REVENGE TRAGEDY PDF

One of these patients required catheter removal due to severe peritonitis.

Use of Tenckhoff Catheter for Peritoneal Dialysis in Terminal Renal Failure

Abstract Over a period of 33 months a total of 2, peritoneal dialyses were carried out by means of indwelling Tenckhoff catheters in 65 patients suffering from terminal renal failure.

Surg Laparosc Endosc Percutan Tech ; Med Clin North Am ; The comparison in terms of early complications of a new technique and percutaneous method for the placement of CAPD catheters. The additional mass of the curled catheter keeps the catheter low in the pelvic gutter, resulting in less catheter migration. In the following day she was asymptomatic but abdominal X-ray revealed a newly developed PP, thus Nephrology department decided to remove the catheter and start hemodialysis.

Si continua navegando, consideramos que acepta su uso. Localized genital edema in patients undergoing continuous ambulatory peritoneal dialysis. The preperitoneal tunneling method. Laboratory testing showed a normal white cell count.

Previous article Next article.